Показати скорочений опис матеріалу
dc.contributor.author | Горошков, О. В. | uk |
dc.contributor.author | Мокієнко, А. В. | uk |
dc.contributor.author | Солтик, С. М. | uk |
dc.contributor.author | Дубовик, С. Л. | uk |
dc.contributor.author | Садовий, К. К. | uk |
dc.contributor.author | Красікова, Д. Р. | uk |
dc.contributor.author | Horoshkov, O. V. | en |
dc.contributor.author | Mokienko, A. V. | en |
dc.contributor.author | Soltyk, S. M. | en |
dc.contributor.author | Dubovyk, S. L. | en |
dc.contributor.author | Sadoviy, K. K. | en |
dc.contributor.author | Krasikova, D. R. | en |
dc.date.accessioned | 2025-06-17T12:28:23Z | |
dc.date.available | 2025-06-17T12:28:23Z | |
dc.date.issued | 2025 | |
dc.identifier.citation | Гетеротрофні мікроорганізми у системах розподілу питної води / Горошков О. В. та ін. Актуальні проблеми транспортної медицини. 2025. № 2 (80). С. 72–79. | uk_UA |
dc.identifier.uri | https://repo.odmu.edu.ua:443/xmlui/handle/123456789/17788 | |
dc.description.abstract | Мета огляду полягала в аналізі даних літератури гетеротрофні мікроорганізми у питній воді (HPC) для оцінки використання цього показника для моніторингу біологічної стабільності та факторів, що впливають на її рівень. Продемонстровано зв’язок між кількістю колоній HPC і різними фізичними та хімічними параметрами в системах розподілу води. Показано, що сам дезінфікуючий засіб не може запобігти утворенню біоплівки в системах розподілу води. Встановлено вплив очищення води, температури та час перебування на рівень HPC та необхідність інтегрованого способу контролю НРС внаслідок наявності багатьох змінних. Представлено сукупні докази щодо відсутності стандартизації при використанні HPC як інструменту для моніторингу якості питної води. Обгрунтовано використання HPC як адекватного параметру для моніторингу біологічної стійкості води та змін її якості в системах розподілу. | uk_UA |
dc.description.abstract | The aim of the review was to analyze the literature data on heterotrophic microorganisms in drinking water (HPC) to evaluate the use of this indicator for monitoring biological stability and factors affecting its level. The relationship between the number of HPC colonies and various physical and chemical parameters in water distribution systems was demonstrated. It was shown that disinfectant alone cannot prevent the formation of biofilm in water distribution systems. The influence of water treatment, temperature and residence time on HPC levels was established and the need for an integrated approach to HPC control due to the presence of many variables was presented. The cumulative evidence on the lack of standardization in the use of HPC as a tool for monitoring drinking water quality was presented. The use of HPC as an adequate parameter for monitoring biological stability of water and changes in its quality in distribution systems was justified. | en |
dc.language.iso | uk | en |
dc.subject | біологічна стабільність | uk_UA |
dc.subject | число гетеротрофних мікроорганізмів | uk_UA |
dc.subject | мікробна якість води | uk_UA |
dc.subject | система водорозподілу | uk_UA |
dc.subject | biological stability | en |
dc.subject | heterotrophic plate count | en |
dc.subject | microbial water quality | en |
dc.subject | water distribution system | en |
dc.title | Гетеротрофні мікроорганізми у системах розподілу питної води | uk_UA |
dc.title.alternative | Heterotrophic microorganisms in drinking water distribution systems | en |
dc.type | Article | en |